ER30XCN25DPOY-E2

Output method: PNP
Installation method: non-buried
Detection distance: 25 mm
Current consumption: ≤20mA
Protection circuit: short circuit protection, overload protection, reverse polarity protection
Impact resistance: 30 g/11ms,X、Y、Z Directions 3 times each

Technical Parameters
Dimensions
Connection Diagram
Output method PNP
Installation method Non-buried
Detection distance 25mm
Consumption of current ≤20mA
Protection circuit Short circuit protection, overload protection, reverse polarity protection
Impact resistance 30g/11ms,X、Y、Z Directions 3 times each
High pressure resistance 1000V/AC 50/60Hz 60s
Protection level IP67
Product Certification CE、UL
Housing material Nickel-Copper Alloy
Connection method M12 Connector
Ensure distance ≤18mm
Appearance specifications M30*1.5*79mm
Standard target Fe 75*75*1t( Grounding)
Hysteresis range 3…20%
Repeat error ≤5%
Load current ≤200mA
Residual voltage ≤2V
Switching frequency 25Hz
Output status NO
Adjustment method Multi-turn potentiometer (electrical adjustment >10 lock up)
Adjust the distance 4...30mm