BR18XBN08DNOA-E2

Product function: Anti-strong magnetic immunity
Installation method: non-buried
Detection distance: 8 mm
Ensure distance: 0…6.4 mm
Standard target: Fe 24*24*1t
Appearance specifications (cylindrical): M18*1*71mm

 

Technical Parameters
Dimensions
Connection Diagram
Product Features Anti-strong magnetic immunity
Installation method Non-buried
Detection distance 8mm
Ensure distance 0…6.4mm
Standard target Fe 24*24*1t
Appearance specifications (cylindrical) M18*1*71mm
Output method NPN
Output status NO
Residual voltage ≤2.5V
Power supply voltage 10…30VDC
Load current ≤200mA
Switching frequency 1000Hz
Switch point offset ≤±10%
Hysteresis range 1…20%
Repeat error ≤3%
Ambient temperature -25℃…70℃
Leakage current ≤15mA
Protection circuit Short circuit protection, overload protection, reverse polarity protection
Strong magnetism 100mT
Impact pressure resistance 1000V/AC 50/60Hz 60s
Insulation impedance ≥50M Oh (500VDC)
Vibration resistance Complex amplitude 1.5 mm 10…50Hz(X,Y,Z Directions 2 hours each )
Protection level IP 67
Output Instructions yellow LED
Housing material brass +PTFE coating
Product Certification CE
Connection method M12 Connector